Canon IR 5070 is a digital black & white copier machine with 50 copies/pages per minute. Drum stated yield is 3,000,000 and one toner cartridge makes about 45,000 A4 pages at 6% .
Fusing Cleaning Web Replacement:
Slide fuser/feeder unit out. Remove upper cover (one screw). Release the fuser cleaning web by removing front and rear screws. Open up and push the web feed roller and the web take up roller towards the rear to remove. Replace it with the new web. While installing the web make sure that the arm is outside of the roller and that tha new belt has oil in it where it contacts the roller. After repalcing the belt, go to COPIER-COUNTER-MISC-FIX WEB to reset and COPIER- COUNTER- DRBL1- FIX WEB to reset its counter.
Waste Toner:
when waste toner bottle is full E013-0001 will display. Go to service mode COPIER- COUNTER- MISC- WASTE TNE to reset.
Alarm Codes:
- 04 0001Right deck lift06 0003Fuser Web missing11 0001Waste toner full65 0001Punch case full61 0001Staple
Trouble Codes
- E000-000, 0010Fuser did not heat upE001-0001, 0002, 0003, 0010Hight Fuser TemperatureE002-0000, 0001, 0010Low Fuser Temperature
These codes must be reset by a service representative. To do so enter service mode, COPIER- FUNCTIONS- CLEAR- ERR. Press OK. Restart the machine
No comments :